Loading the Dye Directory…

DCF

DCF (Ex-Max 501 nm/Em-Max 524 nm)

Dichlorofluorescein (DCF) is an oxidation-sensitive organic probe used to detect the prescence of ROS (reactive oxygen species). Upon oxidation, it has an excitation peak at 501 nm and an emission peak at 524.

Excitation & emission spectra

400450500550600650700750800

Key facts

Excitation maximum
501 nm
Emission maximum
524 nm
Optimal laser line
488
Optimal filter
525/50
Commercial antibodies
2 from 2 suppliers

DCF has an excitation maximum at 501 nm and an emission maximum at 524 nm, a Stokes shift of 23 nm. It is optimally excited by the 488 laser line.

Frequently asked questions

What is DCF?
Dichlorofluorescein (DCF) is an oxidation-sensitive organic probe used to detect the prescence of ROS (reactive oxygen species). Upon oxidation, it has an excitation peak at 501 nm and an emission peak at 524.
What laser excites DCF?
DCF is optimally excited by the 488 laser line. Its excitation maximum is 501 nm.
What filter should I use to detect DCF?
A 525/50 filter captures the peak of the DCF emission near 524 nm with minimal spillover.
How many antibodies are available conjugated to DCF?
FluoroFinder tracks 2 commercially available DCF conjugates, searchable by target, clone, host and application.