Loading the Dye Directory…

BDY FL-X SE

BDY FL-X SE (Ex-Max 504 nm/Em-Max 510 nm)

BDY FL-X SE is excited by the 488 laser and emission captured by the 515/30 filter. It can be used with the following analysis platforms: Fluorescence Microscopy, Immunoassay.

Excitation & emission spectra

400450500550600650700750800

Key facts

Excitation maximum
504 nm
Emission maximum
510 nm
Optimal laser line
488
Optimal filter
515/30
Relative brightness
4 of 5
Extinction coefficient
85000

BDY FL-X SE has an excitation maximum at 504 nm and an emission maximum at 510 nm, a Stokes shift of 6 nm. Its extinction coefficient is 85000 M⁻¹cm⁻¹. It is optimally excited by the 488 laser line.

Frequently asked questions

What is BDY FL-X SE?
BDY FL-X SE is excited by the 488 laser and emission captured by the 515/30 filter. It can be used with the following analysis platforms: Fluorescence Microscopy, Immunoassay.
What laser excites BDY FL-X SE?
BDY FL-X SE is optimally excited by the 488 laser line. Its excitation maximum is 504 nm.
What filter should I use to detect BDY FL-X SE?
A 515/30 filter captures the peak of the BDY FL-X SE emission near 510 nm with minimal spillover.
How bright is BDY FL-X SE?
BDY FL-X SE has a relative brightness of 4 out of 5.